#: locale=en ## Action ### URL LinkBehaviour_49BDD978_5733_30CF_41CD_9EF3205A88FB.source = https://stl.tech/ LinkBehaviour_4AE9855E_5737_30C3_41CE_50F77C31436B.source = https://stl.tech/data-centre-connectivity/copper-and-fibre/ LinkBehaviour_76F79973_5711_10C1_41C6_4D5104D1EE16.source = https://stl.tech/data-centre-connectivity/copper-and-fibre/ LinkBehaviour_496BCA19_562A_0E2E_4175_E9BD9AC2BC09.source = https://stl.tech/data-centre-connectivity/copper-and-fibre/ LinkBehaviour_484352A8_5713_304F_41D3_8A6347238FA6.source = https://stl.tech/data-centre-connectivity/data-centre-interconnect/ LinkBehaviour_4A0B996D_5711_30C1_41C4_4BD1CC008768.source = https://stl.tech/data-centre-connectivity/data-centre-interconnect/ LinkBehaviour_77F1C3F1_5711_77C1_41CE_EB738D03490E.source = https://stl.tech/data-centre-connectivity/data-centre-isp/ LinkBehaviour_42A8BA19_5713_1041_41C1_15EAE7A4A3BA.source = https://stl.tech/data-centre-connectivity/data-centre-isp/ ## Media ### Title photo_5A63ADE9_55DA_05EE_41CB_5FADF82535F4.label = data-centre-interconnect-cable photo_5A10AA91_55DA_0E3F_41B4_C71299594C0A.label = data-centre-splice-bay ## Skin ### Button Button_4D8D7FF6_576F_0FC3_41B8_F24DDB748913.label = Building Fibre Cabling > Button_4D8D7FF7_576F_0FC1_41C2_F8DA6F3419BF.label = Copper Cabling System > Button_4D8C7FF5_576F_0FC1_41D0_4C5624961B94.label = DC Interconnect Solution > Button_4D8D7FF7_576F_0FC1_41C6_6604E91A1606.label = ISP Cabling System > Button_4AEFC55D_5737_30C1_41CA_B92E29295B22.label = Know More >> Button_76F5C972_5711_10C3_41B9_1DF16DCDC3DB.label = Know More >> Button_77F743F0_5711_77DF_419A_D1AD32AA06E3.label = Know More >> Button_484262A7_5713_3041_41B1_432E7FF17A90.label = Know More >> Button_42ABEA18_5713_104F_41C6_A5F9D7D8A11D.label = Know More >> Button_7654600E_562A_1A22_41D1_FEF7FFBC1931.label = Know More >> Button_4A0CA96C_5711_30C7_41C0_28A65F779E38.label = Know More >> ### Image Image_420D80B3_566A_3A62_41C1_280E65164E2A.url = skin/Image_420D80B3_566A_3A62_41C1_280E65164E2A_en.png Image_42AABA10_5713_105F_4181_48B757D07B21.url = skin/Image_42AABA10_5713_105F_4181_48B757D07B21_en.png Image_42AAEA0F_5713_1041_41C7_93C5E9C8454D.url = skin/Image_42AAEA0F_5713_1041_41C7_93C5E9C8454D_en.png Image_42AD0A0E_5713_1043_41C5_C3FBAC6F635B.url = skin/Image_42AD0A0E_5713_1043_41C5_C3FBAC6F635B_en.png Image_42AD9A0C_5713_1047_41CD_B2928A14FB49.url = skin/Image_42AD9A0C_5713_1047_41CD_B2928A14FB49_en.png Image_42B6A28B_566A_1E23_41CD_973E4AA9AE63.url = skin/Image_42B6A28B_566A_1E23_41CD_973E4AA9AE63_en.png Image_485852A2_5713_3043_41CE_0BB79D3ED186.url = skin/Image_485852A2_5713_3043_41CE_0BB79D3ED186_en.png Image_485CD2A6_5713_3043_41C2_2564A7CB8C05.url = skin/Image_485CD2A6_5713_3043_41C2_2564A7CB8C05_en.png Image_485CE2A5_5713_3041_41CC_2DDC0A3B0946.url = skin/Image_485CE2A5_5713_3041_41CC_2DDC0A3B0946_en.png Image_485E32A3_5713_3041_41CE_687D789E285C.url = skin/Image_485E32A3_5713_3041_41CE_687D789E285C_en.png Image_485F72A4_5713_3047_41B8_A7B3585380CC.url = skin/Image_485F72A4_5713_3047_41B8_A7B3585380CC_en.png Image_4A002968_5711_30CF_41C8_183F5663311C.url = skin/Image_4A002968_5711_30CF_41C8_183F5663311C_en.png Image_4A0D196B_5711_30C1_41D3_616BA511DA1D.url = skin/Image_4A0D196B_5711_30C1_41D3_616BA511DA1D_en.png Image_4A0D296A_5711_30C3_41D4_C7AA018BB36C.url = skin/Image_4A0D296A_5711_30C3_41D4_C7AA018BB36C_en.png Image_4A0E1969_5711_30C1_41B2_8A7490675C9E.url = skin/Image_4A0E1969_5711_30C1_41B2_8A7490675C9E_en.png Image_4A92254A_5737_30C3_41D5_81480CC7D128.url = skin/Image_4A92254A_5737_30C3_41D5_81480CC7D128_en.png Image_4AEC654B_5737_30C1_41D3_6317DF3183FF.url = skin/Image_4AEC654B_5737_30C1_41D3_6317DF3183FF_en.png Image_4AED554C_5737_30C7_4173_0ED9BEAE5E02.url = skin/Image_4AED554C_5737_30C7_4173_0ED9BEAE5E02_en.png Image_4AEED54C_5737_30C7_4179_BA2F3CC47DAA.url = skin/Image_4AEED54C_5737_30C7_4179_BA2F3CC47DAA_en.png Image_4BE2347C_5711_10C7_41B1_23092184A831.url = skin/Image_4BE2347C_5711_10C7_41B1_23092184A831_en.png Image_4D8C0FF5_576F_0FC1_418F_32AB7EA1A641.url = skin/Image_4D8C0FF5_576F_0FC1_418F_32AB7EA1A641_en.png Image_60296032_5973_1043_41A0_51B246EEA70E.url = skin/Image_60296032_5973_1043_41A0_51B246EEA70E_en.png Image_72AE127A_56DE_3EED_41CB_1A44FE31E5A8.url = skin/Image_72AE127A_56DE_3EED_41CB_1A44FE31E5A8_en.png Image_76812968_5711_10CF_41CB_DAE181536DF1.url = skin/Image_76812968_5711_10CF_41CB_DAE181536DF1_en.png Image_76D35861_5773_10C1_41C5_1FBDC0640A96.url = skin/Image_76D35861_5773_10C1_41C5_1FBDC0640A96_en.png Image_76FC196A_5711_10C3_41C3_EA1575021FBE.url = skin/Image_76FC196A_5711_10C3_41C3_EA1575021FBE_en.png Image_76FC296B_5711_10C1_41C9_460392774FEC.url = skin/Image_76FC296B_5711_10C1_41C9_460392774FEC_en.png Image_76FD8969_5711_10C1_41D4_0EA51A148CFA.url = skin/Image_76FD8969_5711_10C1_41D4_0EA51A148CFA_en.png Image_775138E5_56DA_0BE6_4193_A2609487FB90.url = skin/Image_775138E5_56DA_0BE6_4193_A2609487FB90_en.png Image_776CED69_56DE_0AEE_41CF_634D1EBC4633.url = skin/Image_776CED69_56DE_0AEE_41CF_634D1EBC4633_en.png Image_7782B3EB_5711_77C1_41C9_220750614ADC.url = skin/Image_7782B3EB_5711_77C1_41C9_220750614ADC_en.png Image_77F9E3EF_5711_77C1_41C6_493868A3D10D.url = skin/Image_77F9E3EF_5711_77C1_41C6_493868A3D10D_en.png Image_77FD73EC_5711_77C7_41D5_63D84B6E1E7F.url = skin/Image_77FD73EC_5711_77C7_41D5_63D84B6E1E7F_en.png Image_77FE63EE_5711_77C3_41C7_458AF288AFDD.url = skin/Image_77FE63EE_5711_77C3_41C7_458AF288AFDD_en.png Image_77FFC3ED_5711_77C1_41D3_A53F4633D940.url = skin/Image_77FFC3ED_5711_77C1_41D3_A53F4633D940_en.png ### Label Label_4AEC554B_5737_30C1_41C3_B455962E2C0F.text = Cable Label_4AECA54A_5737_30C3_41A8_80BDE86DEE1E.text = Cable Label_76FC5969_5711_10C1_41D3_F4E0ACB54D8A.text = Cable Label_77B275A0_563B_FA1D_41D2_E3D43E3BB358.text = Cable Label_4A0D8969_5711_30C1_4193_D3B76CC6B8EE.text = Cable Label_7680A968_5711_10CF_41C2_D3647F4E096F.text = Cable Label_485E62A4_5713_3047_41BF_4EA427FBFC58.text = Cable Label_4B449BC4_5733_17C7_41C5_BE7B886D4105.text = Data Centre Label_76D4C87D_563A_0AE7_4194_F0F787E1277D.text = Face Plate Label_77FBB973_563A_0AE2_41CE_5D04D305F791.text = Jack Module Label_765ACD75_563A_0AE7_4170_448B7B3E9007.text = Jack Panel Label_485E82A3_5713_3041_41BE_67294424DC37.text = Joint Closure Label_4A001968_5711_30CF_41C1_91282CC13AB4.text = Joint Closure Label_42AA8A10_5713_105F_41B5_4600B5C5ACE2.text = MPO Cassette Label_77FFF3ED_5711_77C1_41D0_CCBA73E41CEE.text = MPO Cassette Label_77FE13EE_5711_77C3_41D1_BC3D9662C4CB.text = MPO Cassette Panel Label_42AA5A11_5713_1041_41BE_9176A284E979.text = MPO Cassette Panel Label_42AD0A0F_5713_1041_41CA_D6B891CC4E00.text = MPO Trunk & Array Cords Label_77FC63EC_5711_77C7_41C8_CF24E5F86B09.text = MPO Trunk & Array Cords Label_764EACF0_563A_0BFD_41C5_BEE834605979.text = Patch Cord Label_4AED354C_5737_30C7_41C8_1C60F8254D77.text = Patch Cord & Pigtail Label_76FC696A_5711_10C3_41D4_8E62822DF90D.text = Patch Cord & Pigtail Label_77F9C3EF_5711_77C1_41CC_D584B866D17A.text = Patch Cord & Pigtail Label_76D38861_5773_10C1_41D5_CBD0544B5F54.text = Patch Cord & Pigtail Label_76FCF96B_5711_10C1_419B_B7220B9D0B73.text = Patch Panel Label_485C32A6_5713_3043_41B6_35CC6C15FA6C.text = Patch Panel Label_4BE5847C_5711_10C7_41CC_10D1C9CE67C1.text = Patch Panel Label_4AEE455B_5737_30C1_41D2_1965801CDB10.text = Patch Panel Label_485F52A5_5713_3041_41C7_09BA9DF013C0.text = Rack Label_4A0D096A_5711_30C3_41D0_AF99C81B1EB1.text = Rack Label_4B448BC4_5733_17C7_41D1_1763A8F096E8.text = Solution Portfolio Label_4A0CF96B_5711_30C1_41D4_3D6AE3B8AA07.text = Splice Bay Label_485C82A6_5713_3043_41C0_4A6BB42A6C15.text = Splice Bay Label_77FDA3EB_5711_77C1_41B0_C4A3A0CE8EF3.text = Trunk Cable Assembly Label_42AD4A0E_5713_1043_41CA_393D3F3D27F8.text = Trunk Cable Assembly ### Multiline Text HTMLText_4A01E967_5711_30C1_41A1_1B90F8A80335.html =
STL offers comprehensive end-to-end Data Center Interconnect (DCI) solutions designed to meet the growing demands of modern data center architectures. These solutions include high-count ribbon fiber cables, available in configurations ranging from 96 to 6912 fibers, and adhering to international standards such as IEC 60794-5-10, ITU-T, RoHS, and REACH. Additionally, STL provides high-density splice closures that support up to 1728 fibers, suitable for use in aerial, pole, wall, and underground networks, as well as inside handholes and manholes for trunk, branch, and pot-head applications.


For environments requiring high-density transitions, STL offers Splice Bay, a 19” frame-mountable solution capable of supporting up to 2016 splices per bay. This solution is ideal for splicing outdoor cables to indoor cables. STL’s Optical Cross-connect frames provide further scalability, allowing for the organization of up to 4320 fibers in 45U height frames, making them perfect for meet-me-rooms and entrance facilities where outdoor cables transition to indoor infrastructure.
HTMLText_42ADCA0C_5713_1047_41C6_D801B148C9FE.html =
Structured Cabling Systems (SCS) have played a foundational role in data centre infrastructure since the introduction of the ANSI/TIA-942 standard over two decades ago. This standardized architecture enables long-term flexibility, allowing data centres to upgrade to higher-speed transceivers without needing to overhaul existing cabling—making it a future-proof investment.


Designing structured cabling for a data centre, however, involves complex considerations. Network size and architecture, supported protocols such as Ethernet, Fibre Channel, or InfiniBand, varying speed and distance requirements, interface preferences, port densities, and how the network will be managed all influence the cabling design. Every decision must support both current demands and long-term scalability.


Our Data Centre Core Inside Plant (ISP) Solutions offer a full range of high-performance optical fibre cabling using LC, MPO, and VSFF connectors. Solutions are available in single-mode as well as multimode OM3 and OM4 variants. All components are engineered for performance, scalability, and seamless.
HTMLText_4418179A_563A_0622_41BD_377F6AAB7142.html =
The STL Estelan Copper LAN Cabling System delivers a fully integrated solution that includes cables, patch cords, jacks, and connectivity components. Designed to exceed the latest ANSI/TIA 568 and ISO 11801 standards, it supports consistent, high-quality performance across enterprise buildings and data centre environments. Available in Cat6 and Cat6A categories with both unshielded and shielded options, STL Estelan systems are component-compliant and manufactured in ISO 9001 certified facilities.​


STL also offers a wide portfolio of optical fibre cabling systems engineered for both indoor and outdoor use. These systems include riser cables, patch panels, armored outdoor cables, and more, delivering high-bandwidth, low-latency performance across a range of applications such as data networking, surveillance, and smart building systems. STL fibre solutions comply with TIA 568 and IEEE standards and support network speeds up to 100G and beyond, with options available in single-mode and multimode (OM3 and OM4) variants.
HTMLText_4A96F549_5737_30C1_41CA_C2EFA5740436.html =
The STL Estelan Copper LAN Cabling System delivers a fully integrated solution that includes cables, patch cords, jacks, and connectivity components. Designed to exceed the latest ANSI/TIA 568 and ISO 11801 standards, it supports consistent, high-quality performance across enterprise buildings and data centre environments. Available in Cat6 and Cat6A categories with both unshielded and shielded options, STL Estelan systems are component-compliant and manufactured in ISO 9001 certified facilities.​


STL also offers a wide portfolio of optical fibre cabling systems engineered for both indoor and outdoor use. These systems include riser cables, patch panels, armored outdoor cables, and more, delivering high-bandwidth, low-latency performance across a range of applications such as data networking, surveillance, and smart building systems. STL fibre solutions comply with TIA 568 and IEEE standards and support network speeds up to 100G and beyond, with options available in single-mode and multimode (OM3 and OM4) variants.
HTMLText_4BC6D676_5733_10C3_41BB_6B58DACDC254.html =
Glass to Gigabit Connectivity
HTMLText_4D8D0FFA_576F_0FC3_41B8_300150DDD25E.html =
Company Name
www.loremipsum.com
info@loremipsum.com
Tlf.: +11 111 111 111
HTMLText_76B9152B_5711_1041_41B8_8DC0476D97C7.html =
Building Fibre Cabling System
HTMLText_4857629F_5713_3041_41D0_D3613E2AB33A.html =
DC Interconnect Solution
HTMLText_75D02D43_5772_F0C1_41B0_037D2313357A.html =
ISP Cabling System
HTMLText_4A94F548_5737_30CF_41CC_F6B662C5EA4F.html =
Building Fibre Cabling System
HTMLText_440A8E34_563E_0666_41C5_9C7982FA1282.html =
Copper Cabling System
HTMLText_4A03B960_5711_30FF_4194_A07A2B20129B.html =
DC Interconnect Solutions
HTMLText_42ACEA0A_5713_1043_41D3_A7DD5FB5710B.html =
Data Centre ISP Solution
HTMLText_7E7D9229_5737_1041_41C4_B29FD4781F03.html =
Guide to Explore This Interactive Tour
## Tour ### Description ### Title tour.name = STL-DC-360-Interactive